MWG Touchscreen Electric Control Panel for R.O. Systems
- Up to triple conductivity meter outputs, eight universal inputs, and one temperature sensor; In this way you can:
- Command the high pressure pump and the two solenoid valves for feed interception and flushing; Manage and program the most common measurement and signal instruments installed on the system, with highly flexible ways
- of working
- Manage and setting the automatic cleaning system
- Conform to CE Directives
- Microprocessor
- Touch Screen display 4,3''
- Power supply 230VAC 50-60Hz
- Available in ABS box with protection class IP65 (ref. DG142) or Rack version (ref. DG142R)
- Supplied without conductivity probes
- Control panel version (300 mm H x 200 mm W x 160 mm D)
- RACK Version: H 223 mm, W 155 mm, D 80 mm.
Operating functions:
- High pressure pump (max power load 1 kW), solenoid valves 50W, dosing pump 100W
- Feed electric valve
- Flushing electric valve
- Cleaning electric valve
- Dosing pump for antiscaling.
Features: Signals: 1 – Filter Pressure 2 – Inlet Pressure 3 – R.O. Membrane Inlet Pressure 4 – Concentrate Pressure 5 – Water
- Temperature 6 – Pump Temperature 7 – Standby Position
- Manual Inputs: 1 – R.O. Start 2 – Flushing Start 3 – Processes Stop
- Sensor Transmitter Connections: 1 – 4-20 mA 2 – 0-10 V 3 – Binary / Pulse Connection
- Float Manage: 1 – Analog Sensor 2 – Single Floater 3 – Double Floater
- Flux Sensor Inlet / Outlet / Concentrate and Recycle Line / Cleaning: 1 – Pulse 2 – 4-20mA 3 – 0-10 V
- Water temperature and pump temperature sensor: 1 – Selection by Temperature Sensor 2 – 4-20mA 3 – 0-10 V; Pressure sensors management: 1 – Pretreatment pressure 2 – Inlet pressure 3 – R.O. membrane inlet pressure 4 – Concentrate
- pressure : 1 – NC 2 – NO 3 – 4-20mA 4 – 0-10 V
- Connections: 1 – RS485 Modbus Protocol 2 – CANbus
- Data History: 1 – Service History 2 – Error History
- Maximum Conductivity Inlet: 99.900 us / cm
- Maximum Conductivity Outlet: 999 us / cm
- Additional Data: Conductivity /Alarms /Maintenance
- Delay Time Management up to 999 seconds
- Note: this product does not feature a power cable.
| Ref | Description | Fam. | Subfa m. | Disp. Stock | |
|---|---|---|---|---|---|
| DG142 | TOUCH SCREEN CONTROL PANEL | 30 | 185 | OK | |
| DG142R | TOUCH SCREEN RACK CONTROL PANEL | 30 | 185 | OK |
Conductivity probe
| Ref | Description | Fam. | Subfa m. | Disp. Stock | |
|---|---|---|---|---|---|
| DG121 | MWG CONDUCTIVITY PROBE INOX K=1 CONN.3/4˝ W/CABLE | 30 | 185 | OK | |
| DG122 | MWG CONDUCTIVITY PROBE INOX K=0.1 CONN.3/4˝ W/CABLE | 30 | 185 | OK |
| Certificates | Manufacturer | Sectors |
|---|---|---|
| CE | MWG | Commercial, Industrial |
R.O. PLUS Electric Control Panel for R.O. Systems
- With double conductivity meter (feed and permeate); In this way you can:
- Command the high pressure pump and the two solenoid valves for feed interception and flushing; Manage and program the most common measurement and signal instruments installed on the system, with highly flexible ways
- of working
- Manage and setting the automatic cleaning system
- Conform to CE Directives
- Microprocessor
- LCD display 2 x 16 digit
- Power supply 230VAC 50-60Hz
- Available in ABS box with protection class IP65 (ref. DG101 and ref. DG103) or Rack version (ref. DG101R and ref. DG103R)
- Supplied without conductivity probes.
RACK Version: Height 180 (mm), Width 220 (mm), Dept 80 (mm) Operated functions:
- High pressure pump (max power 736 W)
- Feed electric valve
- Fluxing electric valve
- Cleaning electric valve
- Pump for antiscaling.
External input receivable:
- Low permeate storage tank level
- High permeate storage tank level
- Minimum pressure meter
- Maximum pressure meter
- Pretreatment (filter or softener) in service
- Heat pump
- Failed dosage alarm
- Stand-by.
Alarms: High conductivity; – Low pressure; – High pressure; – Heat pump; – HIGH LOW CONTACT.
| Ref | Description | Fam. | Subfa m. | Disp. Stock | |
|---|---|---|---|---|---|
| DG101 | MWG R.O. PLUS LC CONTROL PANEL | 30 | 185 | OK | |
| DG103 | MWG R.O. PLUS HC CONTROL PANEL | 30 | 185 | OK | |
| DG101R | MWG R.O. PLUS LC RACK CONTROL PANEL | 30 | 185 | OK | |
| DG103R | MWG R.O. PLUS HC RACK CONTROL PANEL | 30 | 185 | OK |
Conductivity meter: The RO PLUS is available in the following two versions (both supplied without conductivity probes). VERSION 1: RO PLUS LC (ref. DG101 ABS box IP65 and ref. DG101R Rack version). With conductivity meter for feed 00,0 ÷ 9,99 mS/cm and conductivity meter for permeate 00,0 ÷ 99,9 µS/cm. Warning: with this model you must use one Stainless Steel probe K=1 (ref. DG121) for feed and one Stainless Steel probe for permeate (ref. DG122), to buy separately. VERSION 2: RO PLUS HC (ref. DG103 ABS box IP65 and ref. DG103R Rack version) With conductivity meter for feed 00,0 ÷ 9,99 mS/cm and conductivity meter for permeate 00,0 ÷ 999 µS/cm Warning: with this model you must use n.2 graphite probes K=1 (ref. DG123), one for the feed and one for the permeate, to buy separately. The version is displayed turning on the instrument. Conductivity probe
| Ref | Description | Fam. | Subfa m. | Disp. Stock | |
|---|---|---|---|---|---|
| DG121 | MWG CONDUCTIVITY PROBE INOX K=1 CONN.3/4˝ W/CABLE | 30 | 185 | OK | |
| DG122 | MWG CONDUCTIVITY PROBE INOX K=0.1 CONN.3/4˝ W/CABLE | 30 | 185 | OK | |
| DG123 | MWG CONDUCTIVITY PROBE GRAPHITE K=1 CONN.3/4˝ W/CABLE | 30 | 185 | OK |
| Certificates | Manufacturer | Sectors |
|---|---|---|
| CE | MWG | Commercial, Industrial |